{"product_id":"schneider-electric-9055-no116-industrial-magnetic-relay","title":"Schneider Electric 9055-NO116 Industrial Magnetic Relay","description":"\u003cdiv class=\"\" data-turn-id-container=\"request-WEB:ca6b811d-4c92-4b87-b038-7715d1d55a6b-83\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:ca6b811d-4c92-4b87-b038-7715d1d55a6b-83\" data-turn-id-container=\"request-WEB:ca6b811d-4c92-4b87-b038-7715d1d55a6b-83\" data-testid=\"conversation-turn-168\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-15 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"11f9c19e-d9ff-4cf6-8f4f-a056e4966b8d\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003ch3 data-section-id=\"17lc1ru\" data-start=\"0\" data-end=\"16\"\u003eDescription:\u003c\/h3\u003e\n\u003cp data-start=\"18\" data-end=\"626\"\u003eThe \u003ca href=\"https:\/\/plgautomation.com\/collections\/square-d\"\u003eSquare D\u003c\/a\u003e 9055-NO116 Magnetic Relay is used to provide instantaneous current sensing and electrical switching for motor protection, overload detection, and industrial control circuits. Commonly installed in motor control centers, switchgear, industrial control panels, conveyor systems, pumps, and heavy manufacturing equipment requiring magnetic current relay protection. Maintenance technicians and \u003ca href=\"https:\/\/plgautomation.com\/collections\/hmi-operator-interfaces\"\u003esystem integrators\u003c\/a\u003e use this relay for equipment repair, retrofit, expansion, and replacement to maintain reliable current monitoring and protective control functions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ms9th\" data-start=\"628\" data-end=\"645\"\u003eApplications:\u003c\/h3\u003e\n\u003cp data-start=\"647\" data-end=\"1123\"\u003eThe Square D 9055-NO116 is a dashpot-type magnetic current relay designed to trip instantly when the preset current threshold is reached. It is suitable for both AC and DC circuits and is commonly used for motor overload protection, jam detection, and protective interlocking in industrial automation systems. The relay features automatic reset as standard and is designed for continuous-duty service in demanding industrial environments. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"5hg6bl\" data-start=\"1125\" data-end=\"1154\"\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cp data-start=\"1156\" data-end=\"1998\"\u003e• Manufacturer: Square D (Schneider Electric)\u003cbr data-start=\"1201\" data-end=\"1204\"\u003e• Part Number: 9055-NO116 (9055 NO116)\u003cbr data-start=\"1242\" data-end=\"1245\"\u003e• Product Type: Magnetic Current Relay\u003cbr data-start=\"1283\" data-end=\"1286\"\u003e• Series: Class 9055 Dashpot Magnetic Relay\u003cbr data-start=\"1329\" data-end=\"1332\"\u003e• Relay Type: Instantaneous Trip Magnetic Current Relay\u003cbr data-start=\"1387\" data-end=\"1390\"\u003e• Function: Motor Overload and Current Monitoring\u003cbr data-start=\"1439\" data-end=\"1442\"\u003e• Maximum Voltage: 600 VAC \/ 250 VDC\u003cbr data-start=\"1478\" data-end=\"1481\"\u003e• Continuous Contact Rating: 10 A\u003cbr data-start=\"1514\" data-end=\"1517\"\u003e• Maximum Pilot Duty: 750 VA at 600 VAC; 100 VA at 250 VDC\u003cbr data-start=\"1575\" data-end=\"1578\"\u003e• Reset Type: Automatic Reset (Hand Reset Optional)\u003cbr data-start=\"1629\" data-end=\"1632\"\u003e• Contact Configuration: SPST Normally Closed (Normally Open Available as Optional Form Y44)\u003cbr data-start=\"1724\" data-end=\"1727\"\u003e• Mounting: Panel Mount\u003cbr data-start=\"1750\" data-end=\"1753\"\u003e• Application: AC and DC Industrial Control Circuits\u003cbr data-start=\"1805\" data-end=\"1808\"\u003e• Typical Applications: Motor starters, conveyor systems, pumps, compressors, machine tools, industrial control panels, and overload protection systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1cz0398\" data-start=\"2000\" data-end=\"2024\"\u003eCommon Replacements:\u003c\/h3\u003e\n\u003cp data-start=\"2026\" data-end=\"2133\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e• Square D 9055-NO117\u003cbr data-start=\"2047\" data-end=\"2050\"\u003e• Square D 9055-NO118\u003cbr data-start=\"2071\" data-end=\"2074\"\u003e• Square D 9055-NO119\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"PLG Automation ","offers":[{"title":"New","offer_id":51727337193774,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0940\/0818\/1038\/files\/Ebay_website_image_9dcd1eb4-d016-41df-a359-51d90f2ef0f2.jpg?v=1770582503","url":"https:\/\/plgautomation.com\/products\/schneider-electric-9055-no116-industrial-magnetic-relay","provider":"PLG Automation ","version":"1.0","type":"link"}