{"product_id":"schneider-electric-lc2d09b-reversing-motor-starter","title":"Schneider Electric LC2D09B Reversing Motor Starter","description":"\u003ch3 data-section-id=\"17lc1ru\" data-start=\"0\" data-end=\"16\" class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription:\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"17\" data-end=\"592\"\u003eThe \u003ca href=\"https:\/\/plgautomation.com\/collections\/schneider-electric\"\u003eSchneider Electric\u003c\/a\u003e LC2D09B Reversing Motor Starter is used in \u003ca href=\"https:\/\/plgautomation.com\/collections\/drives-motor-control\"\u003emotor control systems\u003c\/a\u003e to provide forward and reverse operation of three-phase electric motors with integrated overload protection housed in a UL-listed enclosure. Commonly installed in conveyors, pumps, fans, mixers, and material handling equipment requiring enclosed directional motor control. Maintenance teams, OEM machine builders, and system integrators use this motor starter for equipment replacement, control panel retrofits, and industrial machine installations. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ms9th\" data-start=\"594\" data-end=\"611\"\u003eApplications:\u003c\/h3\u003e\n\u003cp data-start=\"612\" data-end=\"1190\"\u003eThe Schneider Electric LC2D09B reversing motor starter is commonly used in manufacturing facilities, packaging equipment, conveyor systems, pumping stations, and process automation machinery where reliable motor reversing and overload protection are required. The enclosed design provides additional environmental and personnel protection, making it suitable for industrial installations requiring a self-contained motor control solution. The 24V control coil allows integration with PLC systems and low-voltage industrial control circuits. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"5hg6bl\" data-start=\"1192\" data-end=\"1221\"\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cp data-start=\"1222\" data-end=\"2133\"\u003e• Manufacturer part number (MPN): LC2D09B\u003cbr data-start=\"1263\" data-end=\"1266\"\u003e• Manufacturer: Schneider Electric\u003cbr data-start=\"1300\" data-end=\"1303\"\u003e• Product type: Reversing motor starter with UL enclosure\u003cbr data-start=\"1360\" data-end=\"1363\"\u003e• Motor rating at 220 VAC: 1 HP\u003cbr data-start=\"1394\" data-end=\"1397\"\u003e• Adjustable overload current range: 2.5 to 4 A\u003cbr data-start=\"1444\" data-end=\"1447\"\u003e• Coil voltage: 24 VAC\u003cbr data-start=\"1469\" data-end=\"1472\"\u003e• Coil frequency: 50\/60 Hz\u003cbr data-start=\"1498\" data-end=\"1501\"\u003e• Enclosure type: UL-listed enclosed starter assembly\u003cbr data-start=\"1554\" data-end=\"1557\" data-is-only-node=\"\"\u003e• Function: Forward and reverse motor control with overload protection\u003cbr data-start=\"1627\" data-end=\"1630\"\u003e• Interlocking type: Mechanical and electrical interlock\u003cbr data-start=\"1686\" data-end=\"1689\"\u003e• Control components: Start\/stop pushbuttons and reversing controls\u003cbr data-start=\"1756\" data-end=\"1759\"\u003e• Mounting type: Surface mount enclosure\u003cbr data-start=\"1799\" data-end=\"1802\"\u003e• Application: Industrial motor control systems\u003cbr data-start=\"1849\" data-end=\"1852\"\u003e• Duty type: Continuous industrial operation\u003cbr data-start=\"1896\" data-end=\"1899\"\u003e• Operating environment: Manufacturing and material handling facilities\u003cbr data-start=\"1970\" data-end=\"1973\"\u003e• Protection features: Thermal overload and motor protection\u003cbr data-start=\"2033\" data-end=\"2036\"\u003e• Typical control method: PLC or relay-controlled operation \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1cz0398\" data-start=\"2135\" data-end=\"2159\"\u003eCommon Replacements:\u003c\/h3\u003e\n\u003cp data-start=\"2160\" data-end=\"2331\"\u003e• Schneider Electric LC2D12B reversing motor starter\u003cbr data-start=\"2212\" data-end=\"2215\"\u003e• Schneider Electric \u003ca href=\"https:\/\/plgautomation.com\/products\/lc2d09m7-schneider-electric-starter?_pos=1\u0026amp;_sid=4fa5d1274\u0026amp;_ss=r\"\u003eLC2D09M7 \u003c\/a\u003ereversing starter assembly\u003cbr data-start=\"2271\" data-end=\"2274\"\u003e• Schneider Electric TeSys D enclosed reversing starter\u003c\/p\u003e","brand":"PLG Automation ","offers":[{"title":"New","offer_id":51726792065326,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0940\/0818\/1038\/files\/Ebay_website_image_ff333623-a797-4ef1-b7c6-e9437ea7cbcb.jpg?v=1770580577","url":"https:\/\/plgautomation.com\/products\/schneider-electric-lc2d09b-reversing-motor-starter","provider":"PLG Automation ","version":"1.0","type":"link"}