{"product_id":"tekran-instruments-90-33500-00-thermal-converter","title":"Tekran Instruments 90-33500-00 Thermal Converter","description":"\u003cdiv class=\"\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-8 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003ch3\u003eDescription:\u003c\/h3\u003e\n\u003cp\u003eThe Tekran Instruments 90-33500-00 Thermal Converter is used to thermally convert mercury species for continuous mercury emissions monitoring in industrial flue gas applications. Commonly installed in Tekran Model 3320 and 3321 Mercury Continuous Emissions Monitoring (HgCEM) Systems at power plants, cement facilities, waste incinerators, industrial boilers, and other regulated combustion sources to support accurate mercury speciation and emissions compliance. Maintenance technicians, environmental engineers, and \u003ca href=\"https:\/\/plgautomation.com\/collections\/hmi-operator-interfaces\"\u003esystem integrators\u003c\/a\u003e use this thermal converter for routine maintenance, emissions monitoring system repair, preventive servicing, and replacement of worn or degraded converter assemblies. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eThe Tekran Instruments 90-33500-00 Thermal Converter is designed as a replacement thermal conversion assembly for Tekran 3320 and 3321 mercury monitoring systems. It converts oxidized and elemental mercury species within the sampling system to ensure accurate continuous emissions measurements while maintaining compliance with environmental regulations. The converter is commonly used in continuous emissions monitoring systems (CEMS), coal-fired power generation, hazardous waste incineration, cement manufacturing, industrial process monitoring, and environmental testing laboratories. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cp\u003e• Manufacturer: Tekran Instruments Corporation (TSI Company)\u003cbr\u003e• Part Number: 90-33500-00\u003cbr\u003e• Product Type: Thermal Converter Assembly\u003cbr\u003e• Function: Mercury Thermal Conversion for Continuous Emissions Monitoring\u003cbr\u003e• Compatible Systems: Tekran Model 3320 and Model 3321 Mercury Continuous Emissions Monitoring (HgCEM) Systems\u003cbr\u003e• System Type: Continuous Emissions Monitoring System (CEMS)\u003cbr\u003e• Installation: Direct Replacement Thermal Converter Assembly\u003cbr\u003e• Sampling Application: Industrial Flue Gas Mercury Analysis\u003cbr\u003e• Measurement Technology: Thermal Conversion for Mercury Speciation Monitoring\u003cbr\u003e• Compatible Industries: Power Generation, Cement Manufacturing, Waste Incineration, Industrial Boilers, Mining, and Environmental Monitoring Facilities\u003cbr\u003e• Maintenance Use: Preventive Maintenance, Component Replacement, and System Repair\u003cbr\u003e• Compliance Support: Continuous Mercury Emissions Monitoring for Regulatory Reporting and Environmental Compliance. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCommon Replacements:\u003c\/h3\u003e\n\u003cp\u003e• Tekran 3320 Thermal Converter Assembly\u003cbr\u003e• Tekran 3321 Thermal Converter Assembly\u003cbr\u003e• Tekran 3400 Series Thermal Converter Assembly\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Tekran","offers":[{"title":"New","offer_id":51713815380270,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0940\/0818\/1038\/files\/Ebay_website_image_176b73b0-52ca-4f93-b48a-058e44122da6.jpg?v=1770408861","url":"https:\/\/plgautomation.com\/products\/tekran-instruments-90-33500-00-thermal-converter","provider":"PLG Automation ","version":"1.0","type":"link"}