{"product_id":"tele-haase-elektronik-gmbh-r2x-vde0435-time-relay","title":"Tele Haase Elektronik GmbH R2X VDE0435 Time Relay","description":"\u003cdiv class=\"\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-8 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003ch3\u003eDescription:\u003c\/h3\u003e\n\u003cp\u003eThe Tele Haase Elektronik GmbH R2X VDE0435 Time Relay is used to provide adjustable time-delay control for industrial automation and electrical control circuits, enabling delayed switching, machine sequencing, and process timing functions. Commonly installed in industrial control panels, \u003ca href=\"https:\/\/plgautomation.com\/collections\/drives-motor-control\"\u003emotor\u003c\/a\u003e control centers, conveyor systems, packaging machinery, HVAC equipment, and process automation systems requiring reliable timing control. Maintenance technicians, automation engineers, and \u003ca href=\"https:\/\/plgautomation.com\/collections\/hmi-operator-interfaces\"\u003esystem integrators\u003c\/a\u003e use this time relay for equipment repair, control system upgrades, preventive maintenance, and replacement of legacy timing relays. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eThe Tele Haase Elektronik GmbH R2X VDE0435 Time Relay is commonly used in motor starting circuits, pump control systems, conveyor automation, machine sequencing, packaging equipment, HVAC controls, and industrial process control applications where adjustable on-delay, off-delay, pulse, or interval timing functions are required. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cp\u003e• Manufacturer: Tele Haase Elektronik GmbH (TELE Haase Steuergeräte)\u003cbr\u003e• Model: R2X\u003cbr\u003e• Standard Marking: VDE 0435\u003cbr\u003e• Product Type: Time Relay\u003cbr\u003e• Series: VOX R2X\u003cbr\u003e• Function: Adjustable industrial time-delay relay\u003cbr\u003e• Timing Functions: 14 selectable timing functions (model dependent)\u003cbr\u003e• Time Ranges: 14 selectable ranges from 125 ms to 30 hours\u003cbr\u003e• Output Contacts: 2 Changeover (DPDT) contacts\u003cbr\u003e• Contact Rating: 5 A at 250 VAC\u003cbr\u003e• Maximum Switching Capacity: 1000 VA\u003cbr\u003e• Supply Voltage: Plug-in power supply, 12 to 440 VAC or 6 to 110 VDC (module dependent)\u003cbr\u003e• Accuracy: ≤0.5% repeatability under constant conditions\u003cbr\u003e• Reset Time: ≤100 ms\u003cbr\u003e• Mounting: 35 mm DIN rail\u003cbr\u003e• Protection Rating: IP40 housing, IP20 terminals\u003cbr\u003e• Operating Temperature: -25 °C to +55 °C\u003cbr\u003e• Compliance: VDE 0435, VDE 0110, IEC standards\u003cbr\u003e• OEM Status: Genuine Tele Haase industrial timing relay component \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCommon Replacements:\u003c\/h3\u003e\n\u003cp\u003e• Tele Haase R2X20\u003cbr\u003e• Tele Haase R2X24\u003cbr\u003e• Tele Haase R3V20\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Tele","offers":[{"title":"New","offer_id":51713818558766,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0940\/0818\/1038\/files\/Ebay_website_image_1d003d97-f2de-40d0-8ba0-583d5eef5b9e.jpg?v=1770408939","url":"https:\/\/plgautomation.com\/products\/tele-haase-elektronik-gmbh-r2x-vde0435-time-relay","provider":"PLG Automation ","version":"1.0","type":"link"}