{"product_id":"telebyte-model-365-serial-interface-converter","title":"Telebyte Model 365 Serial Interface Converter","description":"\u003cdiv class=\"\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-8 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003ch3\u003eDescription:\u003c\/h3\u003e\n\u003cp\u003eThe Telebyte Model 365 Serial Interface Converter is used to convert serial communications between RS-232, RS-422, and RS-485 interfaces, enabling reliable data transmission between devices using different serial \u003ca href=\"https:\/\/plgautomation.com\/collections\/networking-communication\"\u003ecommunication\u003c\/a\u003e standards. Commonly installed in industrial automation systems, \u003ca href=\"https:\/\/plgautomation.com\/collections\/plcs-more\"\u003ePLC\u003c\/a\u003e networks, SCADA systems, factory control equipment, laboratory instrumentation, and process control applications requiring serial interface conversion. Maintenance technicians, automation engineers, and \u003ca href=\"https:\/\/plgautomation.com\/collections\/hmi-operator-interfaces\"\u003esystem integrators\u003c\/a\u003e use this interface converter for communication system upgrades, equipment integration, troubleshooting, and replacement of legacy serial communication hardware. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eThe Telebyte Model 365 Serial Interface Converter is commonly used in industrial automation, SCADA systems, PLC communications, manufacturing equipment, data acquisition systems, process control, transportation networks, and telecommunications infrastructure where RS-232 devices must communicate with RS-422 or RS-485 networks over extended distances. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cp\u003e• Manufacturer: Telebyte, Inc.\u003cbr\u003e• Model: 365\u003cbr\u003e• Product Type: Serial Interface Converter\u003cbr\u003e• Function: Converts RS-232 communications to RS-422 or RS-485 interfaces\u003cbr\u003e• Communication Standards: RS-232, RS-422, RS-485\u003cbr\u003e• RS-485 Configuration: User-selectable 2-wire or 4-wire operation\u003cbr\u003e• RS-422 Configuration: Full-duplex communication\u003cbr\u003e• Data Rate: Up to 115.2 kbps\u003cbr\u003e• Interface Selection: User-selectable RS-422 or RS-485\u003cbr\u003e• DTE\/DCE Compatibility: User-selectable switch\u003cbr\u003e• Status Display: Integrated DataSpy® LCD showing transmit, receive, and control signal activity\u003cbr\u003e• RS-232 Connector: DB25 (male or female depending on model)\u003cbr\u003e• RS-422\/RS-485 Connection: Terminal block\u003cbr\u003e• Power Input: 115 VAC standard; optional 220 VAC versions available\u003cbr\u003e• Applications: Industrial automation, PLC networking, SCADA, laboratory instrumentation, and telecommunications\u003cbr\u003e• OEM Status: Genuine Telebyte serial communication interface converter component \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCommon Replacements:\u003c\/h3\u003e\n\u003cp\u003e• Telebyte 365M\u003cbr\u003e• Telebyte 365F\u003cbr\u003e• Telebyte 365M-220\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Telebyte","offers":[{"title":"New","offer_id":51713819050286,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0940\/0818\/1038\/files\/Ebay_website_image_bd8b0d68-8473-45aa-8bfa-416f26df0ec0.jpg?v=1770408950","url":"https:\/\/plgautomation.com\/products\/telebyte-model-365-serial-interface-converter","provider":"PLG Automation ","version":"1.0","type":"link"}