{"product_id":"turck-ms1-33ex0-r-intrinsically-safe-switching-amplifier","title":"Turck MS1-33EX0-R Intrinsically Safe Switching Amplifier","description":"\u003ch3 data-section-id=\"17lc1ru\" data-start=\"0\" data-end=\"16\" class=\"PDq2pG_selectionAnchorContainer\"\u003eDescription:\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"17\" data-end=\"567\" class=\"\"\u003eThe \u003ca href=\"https:\/\/plgautomation.com\/collections\/turck\"\u003eTURCK\u003c\/a\u003e MS1-33EX0-R Switching Amplifier is used in intrinsically safe signal isolation systems for hazardous area \u003ca href=\"https:\/\/plgautomation.com\/collections\/sensors-measurement\"\u003esensors\u003c\/a\u003e and field devices. Commonly installed in chemical processing plants, oil and gas facilities, refineries, tank farms, and process automation systems requiring safe signal transmission between hazardous and non-hazardous areas. Maintenance teams and system integrators use this part for replacement, retrofit, control system expansion, and hazardous area instrumentation upgrades. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ms9th\" data-start=\"569\" data-end=\"586\"\u003eApplications:\u003c\/h3\u003e\n\u003cp data-start=\"587\" data-end=\"962\"\u003eThe TURCK MS1-33EX0-R Switching Amplifier is commonly used in refinery process controls, chemical processing systems, burner management systems, tank monitoring installations, mining operations, and PLC or DCS control panels that require intrinsically safe NAMUR sensor interfacing and hazardous area relay switching functions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5hg6bl\" data-start=\"964\" data-end=\"993\" class=\"PDq2pG_selectionAnchorContainer\"\u003eTechnical Specifications:\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"994\" data-end=\"2210\" class=\"\"\u003e• Manufacturer: TURCK\u003cbr data-start=\"1015\" data-end=\"1018\"\u003e• Model \/ Part number: MS1-33EX0-R\u003cbr data-start=\"1052\" data-end=\"1055\"\u003e• Ident number: 5313102\u003cbr data-start=\"1078\" data-end=\"1081\"\u003e• Product type: Multi-Safe Switching Amplifier\u003cbr data-start=\"1126\" data-end=\"1129\"\u003e• Product series: Multi-Safe Series\u003cbr data-start=\"1163\" data-end=\"1166\"\u003e• Number of channels: 3-channel\u003cbr data-start=\"1197\" data-end=\"1200\"\u003e• Supply voltage: 20-250 VAC or 20-125 VDC universal supply\u003cbr data-start=\"1259\" data-end=\"1262\"\u003e• Frequency: 40-70 Hz\u003cbr data-start=\"1283\" data-end=\"1286\"\u003e• Power consumption: ≤ 3 W\u003cbr data-start=\"1312\" data-end=\"1315\"\u003e• Input type: NAMUR sensors, dry contacts, and potential-free contacts\u003cbr data-start=\"1385\" data-end=\"1388\"\u003e• Input standard: EN 60947-5-6 (NAMUR)\u003cbr data-start=\"1426\" data-end=\"1429\"\u003e• Input voltage: 8 VDC nominal\u003cbr data-start=\"1459\" data-end=\"1462\"\u003e• Input current: 8 mA nominal\u003cbr data-start=\"1491\" data-end=\"1494\"\u003e• Switching threshold: 1.55 mA\u003cbr data-start=\"1524\" data-end=\"1527\"\u003e• Output type: Relay outputs\u003cbr data-start=\"1555\" data-end=\"1558\"\u003e• Relay configuration: 3 relay outputs\u003cbr data-start=\"1596\" data-end=\"1599\"\u003e• Relay switching voltage: Up to 250 VAC or 120 VDC\u003cbr data-start=\"1650\" data-end=\"1653\"\u003e• Switching current: Up to 4 A per output\u003cbr data-start=\"1694\" data-end=\"1697\"\u003e• Switching capacity: Up to 1000 VA \/ 60 W per output\u003cbr data-start=\"1750\" data-end=\"1753\"\u003e• Output mode: Selectable NO\/NC operation\u003cbr data-start=\"1794\" data-end=\"1797\"\u003e• Isolation: Galvanic isolation between input circuits, output circuits, and supply voltage\u003cbr data-start=\"1888\" data-end=\"1891\"\u003e• Hazardous area approval: ATEX II (1) GD, [Ex ia] IIC\u003cbr data-start=\"1945\" data-end=\"1948\"\u003e• Functional safety rating: SIL 2 capable\u003cbr data-start=\"1989\" data-end=\"1992\"\u003e• Mounting: DIN rail mount\u003cbr data-start=\"2018\" data-end=\"2021\"\u003e• Protection rating: IP20\u003cbr data-start=\"2046\" data-end=\"2049\"\u003e• Operating temperature: -25°C to +60°C\u003cbr data-start=\"2088\" data-end=\"2091\"\u003e• Application environment: Industrial hazardous area and process control systems \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1cz0398\" data-start=\"2212\" data-end=\"2236\"\u003eCommon Replacements:\u003c\/h3\u003e\n\u003cp data-start=\"2237\" data-end=\"2419\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e• TURCK IM1-33EX-R Isolating Switching Amplifier\u003cbr data-start=\"2285\" data-end=\"2288\"\u003e• TURCK MK13-33EX0-R Switching Amplifier\u003cbr data-start=\"2328\" data-end=\"2331\"\u003e• TURCK \u003ca href=\"https:\/\/plgautomation.com\/products\/turck-ms1-22ex0-r-switching-amplifier?_pos=2\u0026amp;_sid=31bfcc568\u0026amp;_ss=r\"\u003eMS1-22EX0-R\u003c\/a\u003e Multi-Safe Switching Amplifier\u003c\/p\u003e","brand":"TURCK","offers":[{"title":"New","offer_id":51714301526318,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0940\/0818\/1038\/files\/Ebay_website_image_796e94cd-d48d-4db5-bac2-b37e2a744c92.jpg?v=1770421989","url":"https:\/\/plgautomation.com\/products\/turck-ms1-33ex0-r-intrinsically-safe-switching-amplifier","provider":"PLG Automation ","version":"1.0","type":"link"}