{"product_id":"tylan-general-cdl-11so6-baratron-pressure-transducer","title":"Tylan General CDL-11SO6 Baratron Pressure Transducer","description":"\u003cdiv class=\"\" data-turn-id-container=\"request-6a43a35d-6f44-83ec-bb05-598fd82bfd75-22\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-6a43a35d-6f44-83ec-bb05-598fd82bfd75-22\" data-turn-id-container=\"request-6a43a35d-6f44-83ec-bb05-598fd82bfd75-22\" data-testid=\"conversation-turn-676\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"543facf1-c6ab-4cb5-9a46-4bc682569b3d\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003ch3 data-section-id=\"17lc1ru\" data-start=\"0\" data-end=\"16\"\u003eDescription:\u003c\/h3\u003e\n\u003cp data-start=\"17\" data-end=\"847\"\u003eThe Tylan General CDL-11S06 Baratron Pressure Transducer is a high-precision capacitance diaphragm pressure transducer designed for accurate absolute vacuum pressure measurement in semiconductor, laboratory, and industrial vacuum systems. Commonly installed in vacuum chambers, semiconductor process equipment, analytical instruments, thin-film deposition systems, and research laboratories requiring a 0–10 Torr measurement range. Maintenance technicians, process engineers, and \u003ca href=\"https:\/\/plgautomation.com\/collections\/hmi-operator-interfaces\"\u003esystem integrators\u003c\/a\u003e use this pressure transducer for equipment repair, vacuum process monitoring, calibration, and replacement of failed OEM pressure \u003ca href=\"https:\/\/plgautomation.com\/collections\/sensors-measurement\"\u003esensors\u003c\/a\u003e to maintain precise vacuum control. The Baratron sensor provides gas-independent pressure measurement with excellent long-term stability and repeatability. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ms9th\" data-start=\"849\" data-end=\"866\"\u003eApplications:\u003c\/h3\u003e\n\u003cp data-start=\"867\" data-end=\"1395\"\u003eThe Tylan General CDL-11S06 Baratron Pressure Transducer is commonly used in semiconductor fabrication, chemical vapor deposition (CVD), physical vapor deposition (PVD), plasma etching, vacuum furnaces, leak detection systems, and laboratory vacuum equipment. Its capacitance diaphragm sensing technology delivers highly accurate absolute pressure measurements that are unaffected by gas composition, making it ideal for critical vacuum process control and scientific research applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"5hg6bl\" data-start=\"1397\" data-end=\"1426\"\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cp data-start=\"1427\" data-end=\"2098\"\u003e• Brand: Tylan General (Millipore)\u003cbr data-start=\"1461\" data-end=\"1464\"\u003e• Model: CDL-11S06\u003cbr data-start=\"1482\" data-end=\"1485\"\u003e• Product Type: Baratron Pressure Transducer\u003cbr data-start=\"1529\" data-end=\"1532\"\u003e• Pressure Range: 0–10 Torr (Absolute)\u003cbr data-start=\"1570\" data-end=\"1573\"\u003e• Sensor Technology: Capacitance Diaphragm Manometer (Baratron®)\u003cbr data-start=\"1637\" data-end=\"1640\"\u003e• Measurement Type: Absolute Pressure\u003cbr data-start=\"1677\" data-end=\"1680\"\u003e• Accuracy: High-Precision Gas-Independent Measurement\u003cbr data-start=\"1734\" data-end=\"1737\"\u003e• Output Signal: Analog Voltage (configuration dependent)\u003cbr data-start=\"1794\" data-end=\"1797\"\u003e• Wetted Materials: All-Welded Stainless Steel Sensor Construction\u003cbr data-start=\"1863\" data-end=\"1866\"\u003e• Process Connection: Vacuum Flange (configuration dependent)\u003cbr data-start=\"1927\" data-end=\"1930\"\u003e• Maximum Operating Pressure: Application Dependent\u003cbr data-start=\"1981\" data-end=\"1984\"\u003e• Application: Semiconductor, Vacuum Process Control, and Laboratory Systems \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1cz0398\" data-start=\"2100\" data-end=\"2124\"\u003eCommon Replacements:\u003c\/h3\u003e\n\u003cp data-start=\"2125\" data-end=\"2345\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e• MKS Instruments 627 Series 10 Torr Baratron Capacitance Manometer\u003cbr data-start=\"2192\" data-end=\"2195\"\u003e• MKS Instruments 626 Series 10 Torr Pressure Transducer\u003cbr data-start=\"2251\" data-end=\"2254\"\u003e• Inficon CDG025D 10 Torr Capacitance Diaphragm Gauge\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Tylan","offers":[{"title":"Used Surplus - Excellent Condition","offer_id":51714350088494,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0940\/0818\/1038\/files\/Ebay_website_image_af5d8ef2-5a9d-4a49-b4e5-8efa103d7112.jpg?v=1770423705","url":"https:\/\/plgautomation.com\/products\/tylan-general-cdl-11so6-baratron-pressure-transducer","provider":"PLG Automation ","version":"1.0","type":"link"}