{"product_id":"tylan-instruments-fc-2900v-mass-flow-controller","title":"Tylan Instruments FC-2900V Mass Flow Controller","description":"\u003cdiv data-is-intersecting=\"true\" data-turn-id-container=\"request-6a467d74-de54-83ec-be15-35156863671e-1\" class=\"\"\u003e\n\u003csection data-turn=\"assistant\" data-testid=\"conversation-turn-36\" data-turn-id-container=\"request-6a467d74-de54-83ec-be15-35156863671e-1\" data-turn-id=\"request-6a467d74-de54-83ec-be15-35156863671e-1\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" data-conversation-screenshot-content=\"\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-message-model-slug=\"gpt-5-5\" dir=\"auto\" data-turn-start-message=\"true\" data-message-id=\"245f0d4d-9e75-4100-9024-00f4ba528a88\" data-message-author-role=\"assistant\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003ch3 data-end=\"16\" data-start=\"0\" data-section-id=\"17lc1ru\"\u003eDescription:\u003c\/h3\u003e\n\u003cp data-end=\"583\" data-start=\"18\"\u003eThe TYLAN FC-2900V Mass Flow Controller 200 SCCM H2 is used in precision gas flow control systems for semiconductor manufacturing, laboratory instrumentation, and industrial process automation. Commonly installed in semiconductor processing equipment, gas delivery systems, vacuum systems, analytical instruments, and research laboratories requiring accurate hydrogen gas flow regulation. Maintenance teams and \u003ca href=\"https:\/\/plgautomation.com\/collections\/hmi-operator-interfaces\"\u003esystem integrators\u003c\/a\u003e use this mass flow controller for repair, retrofit, replacement, and process automation upgrades. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"602\" data-start=\"585\" data-section-id=\"5ms9th\"\u003eApplications:\u003c\/h3\u003e\n\u003cp data-end=\"1087\" data-start=\"604\"\u003eThe TYLAN FC-2900V Mass Flow Controller 200 SCCM H2 is designed to accurately measure and regulate hydrogen gas flow in high-purity process applications. It is widely used in semiconductor fabrication, chemical vapor deposition (CVD) systems, vacuum coating equipment, gas blending panels, analytical instrumentation, pharmaceutical manufacturing, fuel cell research, and laboratory environments where precise hydrogen flow control is essential. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"1118\" data-start=\"1089\" data-section-id=\"5hg6bl\"\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cp data-end=\"1978\" data-start=\"1120\"\u003e• Manufacturer: TYLAN General (Millipore)\u003cbr data-end=\"1164\" data-start=\"1161\"\u003e• Part Number: FC-2900V\u003cbr data-end=\"1190\" data-start=\"1187\"\u003e• Product Type: Mass Flow Controller\u003cbr data-end=\"1229\" data-start=\"1226\"\u003e• Function: Precision Hydrogen Gas Flow Measurement and Control\u003cbr data-end=\"1295\" data-start=\"1292\"\u003e• Application: Semiconductor Processing, Laboratory, and Industrial Gas Delivery Systems\u003cbr data-end=\"1386\" data-start=\"1383\"\u003e• Compatible Equipment: TYLAN 2900 Series Gas Control Systems and Semiconductor Process Equipment\u003cbr data-end=\"1486\" data-start=\"1483\"\u003e• Series: 2900 Series\u003cbr data-end=\"1510\" data-start=\"1507\"\u003e• Flow Capacity: 200 SCCM\u003cbr data-end=\"1538\" data-start=\"1535\"\u003e• Calibration Gas: Hydrogen (H₂)\u003cbr data-end=\"1573\" data-start=\"1570\"\u003e• Control Type: Closed-Loop Electronic Mass Flow Control\u003cbr data-end=\"1632\" data-start=\"1629\"\u003e• Input\/Output Signal: 0–5 VDC (Model Dependent)\u003cbr data-end=\"1683\" data-start=\"1680\"\u003e• Power Supply: ±15 VDC Nominal\u003cbr data-end=\"1717\" data-start=\"1714\"\u003e• Valve Type: Normally Closed Proportional Control Valve\u003cbr data-end=\"1776\" data-start=\"1773\"\u003e• Mounting Type: Inline Process Installation\u003cbr data-end=\"1823\" data-start=\"1820\"\u003e• Industrial Duty Construction\u003cbr data-end=\"1856\" data-start=\"1853\"\u003e• Designed for Continuous Service Operation\u003cbr data-end=\"1902\" data-start=\"1899\"\u003e• OEM Replacement Mass Flow Controller \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"2004\" data-start=\"1980\" data-section-id=\"1cz0398\"\u003eCommon Replacements:\u003c\/h3\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"2156\" data-start=\"2006\"\u003e• TYLAN FC-2900V 100 SCCM H2 Mass Flow Controller\u003cbr data-end=\"2058\" data-start=\"2055\"\u003e• TYLAN FC-2900V 500 SCCM H2 Mass Flow Controller\u003cbr data-end=\"2110\" data-start=\"2107\"\u003e• TYLAN FC-2900V 1 SLM H2 Mass Flow Controller\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Tylan","offers":[{"title":"Used Surplus - Excellent Condition","offer_id":51714349924654,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0940\/0818\/1038\/files\/Ebay_website_image_332e2f36-fb41-4a56-a183-99f41c841e23.jpg?v=1770423699","url":"https:\/\/plgautomation.com\/products\/tylan-instruments-fc-2900v-mass-flow-controller","provider":"PLG Automation ","version":"1.0","type":"link"}