{"product_id":"vulcain-va-201r-honeywell-relay-module-va-201r-18-27vac-alarme-tl","title":"Vulcain VA-201R Honeywell Relay Module VA-201R 18-27VAC ALARME TL VA201R","description":"\u003ch3 data-section-id=\"17lc1ru\" data-start=\"0\" data-end=\"16\"\u003eDescription:\u003c\/h3\u003e\n\u003cp data-start=\"17\" data-end=\"765\"\u003eThe Vulcain VA-201R Relay Module is used in \u003ca href=\"https:\/\/plgautomation.com\/collections\/sensors-measurement\" title=\"industrial gas detection\"\u003eindustrial gas detection\u003c\/a\u003e and alarm control systems to provide relay-based output control and alarm activation for hazardous area monitoring applications. Commonly installed in Honeywell Vulcain gas detection networks, industrial safety systems, chemical processing facilities, and plant monitoring equipment requiring reliable alarm signaling and relay switching functions. Maintenance teams, plant operators, and safety personnel use this part for replacement, retrofit, and gas detection system maintenance projects. The VA-201R functions as an output expansion module for the VA201C controller and provides multiple relay outputs for alarm and control operations. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ms9th\" data-start=\"767\" data-end=\"784\"\u003eApplications:\u003c\/h3\u003e\n\u003cp data-start=\"785\" data-end=\"1340\"\u003eThe Vulcain VA-201R Relay Module is commonly used in industrial gas detection systems, hazardous location monitoring installations, chemical processing facilities, and plant safety applications requiring dependable alarm output performance. It supports workflows involving gas leak detection, alarm annunciation, ventilation activation, equipment shutdown control, and environmental safety monitoring. The relay module allows indirect activation of external warning and control devices through multiple relay outputs. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"5hg6bl\" data-start=\"1342\" data-end=\"1371\"\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cp data-start=\"1372\" data-end=\"2342\"\u003e• Brand: Vulcain \/ Honeywell\u003cbr data-start=\"1400\" data-end=\"1403\"\u003e• Part Number: VA-201R\u003cbr data-start=\"1425\" data-end=\"1428\"\u003e• Product Type: Relay Module\u003cbr data-start=\"1456\" data-end=\"1459\"\u003e• System Series: VA201 Gas Detection System\u003cbr data-start=\"1502\" data-end=\"1505\"\u003e• Operating Voltage: 18–27 VAC\u003cbr data-start=\"1535\" data-end=\"1538\"\u003e• Module Function: Alarm Relay Expansion Module\u003cbr data-start=\"1585\" data-end=\"1588\"\u003e• Relay Configuration: Up to 8 Relay Outputs\u003cbr data-start=\"1632\" data-end=\"1635\"\u003e• Relay Type: DPDT Relays\u003cbr data-start=\"1660\" data-end=\"1663\"\u003e• Relay Contact Rating: 5 A\u003cbr data-start=\"1690\" data-end=\"1693\"\u003e• Maximum Switching Voltage: 30 VDC or 250 VAC Resistive Load\u003cbr data-start=\"1754\" data-end=\"1757\"\u003e• Function: Alarm Activation and Output Switching\u003cbr data-start=\"1806\" data-end=\"1809\"\u003e• Application: Industrial Gas Detection and Safety Monitoring Systems\u003cbr data-start=\"1878\" data-end=\"1881\"\u003e• Compatible Controller: Vulcain VA201C Controller\u003cbr data-start=\"1931\" data-end=\"1934\"\u003e• Installation Type: Control Panel Mounted Module\u003cbr data-start=\"1983\" data-end=\"1986\"\u003e• Construction Type: Industrial Alarm Relay Interface Module\u003cbr data-start=\"2046\" data-end=\"2049\"\u003e• Monitoring Purpose: Alarm Signaling and Safety System Control\u003cbr data-start=\"2112\" data-end=\"2115\"\u003e• Industrial Use: Chemical Processing, Manufacturing, Utilities, and Hazardous Area Monitoring Applications\u003cbr data-start=\"2222\" data-end=\"2225\"\u003e• Manufacturer Association: Honeywell Analytics \/ Vulcain Gas Detection Systems \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1cz0398\" data-start=\"2344\" data-end=\"2368\"\u003eCommon Replacements:\u003c\/h3\u003e\n\u003cp data-start=\"2369\" data-end=\"2506\"\u003e• Honeywell Vulcain \u003ca href=\"https:\/\/plgautomation.com\/products\/va201m-honeywell-vulcain-va201-gas-detector?_pos=1\u0026amp;_sid=85163358c\u0026amp;_ss=r\" title=\"VA201\"\u003eVA201\u003c\/a\u003e Output Module\u003cbr data-start=\"2408\" data-end=\"2411\"\u003e• Honeywell Analytics Relay Expansion Module\u003cbr data-start=\"2455\" data-end=\"2458\"\u003e• Honeywell Gas Detection Control Relay Module\u003c\/p\u003e","brand":"Vulcain","offers":[{"title":"Used Surplus - Excellent Condition","offer_id":51730475942190,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0940\/0818\/1038\/files\/Ebay_website_image_efaa054e-882c-43df-91b6-8bad3f9cc27d.jpg?v=1770593387","url":"https:\/\/plgautomation.com\/products\/vulcain-va-201r-honeywell-relay-module-va-201r-18-27vac-alarme-tl","provider":"PLG Automation ","version":"1.0","type":"link"}