{"product_id":"westinghouse-2605d15g19-shunt-trip-assembly-ja-ka-2-3-pole","title":"Westinghouse 2605D15G19 Shunt Trip Assembly JA \u0026 KA 2-3 Pole","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-6a17ed1b-5e24-83ec-85eb-0fdeb5aa41eb-36\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-6a17ed1b-5e24-83ec-85eb-0fdeb5aa41eb-36\" data-turn-id-container=\"request-6a17ed1b-5e24-83ec-85eb-0fdeb5aa41eb-36\" data-testid=\"conversation-turn-88\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"d8f0ace0-885f-4360-b056-f9ff1128c097\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003ch3 data-section-id=\"17lc1ru\" data-start=\"0\" data-end=\"16\"\u003eDescription:\u003c\/h3\u003e\n\u003cp data-start=\"17\" data-end=\"716\"\u003eThe Westinghouse 2605D15G19 Shunt Trip Assembly is used in industrial circuit breaker control systems for remote trip activation and auxiliary breaker operation in JA and KA series 2-pole and 3-pole molded case circuit breakers. Commonly installed in switchgear assemblies, \u003ca href=\"https:\/\/plgautomation.com\/collections\/drives-motor-control\"\u003emotor control\u003c\/a\u003e centers, industrial power distribution panels, and emergency shutdown systems requiring dependable remote breaker tripping and electrical safety control functionality. Maintenance electricians, facility engineers, and industrial \u003ca href=\"https:\/\/plgautomation.com\/collections\/hmi-operator-interfaces\"\u003esystem integrators\u003c\/a\u003e use this shunt trip assembly for breaker repairs, replacement maintenance, retrofit projects, and restoration of legacy Westinghouse electrical protection systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ms9th\" data-start=\"718\" data-end=\"735\"\u003eApplications:\u003c\/h3\u003e\n\u003cp data-start=\"736\" data-end=\"1167\"\u003eThe Westinghouse 2605D15G19 shunt trip assembly is commonly used in industrial switchgear systems, MCC assemblies, emergency power shutdown systems, manufacturing facilities, HVAC distribution systems, process \u003ca href=\"https:\/\/plgautomation.com\/collections\/plcs-more\"\u003eautomation equipment\u003c\/a\u003e, utility infrastructure, and electrical protection panels where reliable remote breaker tripping and auxiliary control functionality are required for industrial safety and power management operations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5hg6bl\" data-start=\"1169\" data-end=\"1198\"\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cp data-start=\"1199\" data-end=\"2006\"\u003e• Manufacturer: Westinghouse\u003cbr data-start=\"1227\" data-end=\"1230\"\u003e• Part Number: 2605D15G19\u003cbr data-start=\"1255\" data-end=\"1258\"\u003e• Product Type: Shunt Trip Assembly\u003cbr data-start=\"1293\" data-end=\"1296\"\u003e• Compatible Breaker Series: JA and KA\u003cbr data-start=\"1334\" data-end=\"1337\"\u003e• Pole Compatibility: 2 Pole and 3 Pole\u003cbr data-start=\"1376\" data-end=\"1379\"\u003e• Application Type: Circuit breaker remote trip control\u003cbr data-start=\"1434\" data-end=\"1437\"\u003e• Electrical Function: Remote breaker tripping and auxiliary operation\u003cbr data-start=\"1507\" data-end=\"1510\"\u003e• System Compatibility: Molded case circuit breaker systems\u003cbr data-start=\"1569\" data-end=\"1572\"\u003e• Installation Environment: Switchgear and industrial control panels\u003cbr data-start=\"1640\" data-end=\"1643\"\u003e• Industry Use: Manufacturing and industrial power distribution\u003cbr data-start=\"1706\" data-end=\"1709\"\u003e• Compatible Equipment: MCCs and breaker assemblies\u003cbr data-start=\"1760\" data-end=\"1763\"\u003e• Mounting Type: Internal breaker accessory installation\u003cbr data-start=\"1819\" data-end=\"1822\"\u003e• Frequency Compatibility: 50\/60 Hz industrial applications\u003cbr data-start=\"1881\" data-end=\"1884\"\u003e• Service Application: Replacement and retrofit projects\u003cbr data-start=\"1940\" data-end=\"1943\"\u003e• Equipment Category: Industrial electrical breaker accessory\u003c\/p\u003e\n\u003ch3 data-section-id=\"1cz0398\" data-start=\"2008\" data-end=\"2032\"\u003eCommon Replacements:\u003c\/h3\u003e\n\u003cp data-start=\"2033\" data-end=\"2156\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e• Eaton Series C Shunt Trip Assembly\u003cbr data-start=\"2069\" data-end=\"2072\"\u003e• \u003ca href=\"https:\/\/plgautomation.com\/products\/westinghouse-2605d15g05-120v-circuit-breaker-control-shunt-trip-unit?_pos=1\u0026amp;_psq=2605D15G05\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eWestinghouse 2605D15G05 Shunt Trip Unit\u003c\/a\u003e\u003cbr data-start=\"2113\" data-end=\"2116\"\u003e• Cutler-Hammer JA\/KA Breaker Shunt Trip\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Westinghouse","offers":[{"title":"New","offer_id":51732536557870,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0940\/0818\/1038\/files\/Ebay_website_image_fc65e56a-2b1c-4bda-be01-83ea0b6fa43c.jpg?v=1770599800","url":"https:\/\/plgautomation.com\/products\/westinghouse-2605d15g19-shunt-trip-assembly-ja-ka-2-3-pole","provider":"PLG Automation ","version":"1.0","type":"link"}