{"product_id":"westinghouse-ehd315la02-molded-case-circuit-breaker","title":"Westinghouse EHD315LA02 Molded Case Circuit Breaker","description":"\u003cdiv class=\"relative w-full overflow-visible\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-(--header-height)\" dir=\"auto\" data-turn-id=\"cc0b3afe-7273-4516-ad47-395a008757ae\" data-turn-id-container=\"cc0b3afe-7273-4516-ad47-395a008757ae\" data-testid=\"conversation-turn-17\" data-scroll-anchor=\"false\" data-turn=\"user\"\u003e\u003c\/section\u003e\n\u003cdiv class=\"contents\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"relative w-full overflow-visible\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:60d8ebfd-903e-4106-ad6c-e54249e2033b-8\" data-turn-id-container=\"request-WEB:60d8ebfd-903e-4106-ad6c-e54249e2033b-8\" data-testid=\"conversation-turn-18\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-3 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"d9a54c1b-8752-4a09-bd6e-9665bfd0a814\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003ch3 data-section-id=\"17lc1ru\" data-start=\"0\" data-end=\"16\"\u003eDescription:\u003c\/h3\u003e\n\u003cp data-start=\"18\" data-end=\"498\"\u003eThe Westinghouse EHD315LA02 Molded Case \u003ca href=\"https:\/\/plgautomation.com\/collections\/power-supplies-protection\"\u003eCircuit Breaker\u003c\/a\u003e is used in industrial electrical distribution and branch circuit protection systems. Commonly installed in panelboards, switchboards, motor control centers, and commercial power distribution assemblies requiring reliable overcurrent protection. Maintenance teams, electrical contractors, and system integrators use this breaker for replacement, retrofit, and electrical distribution system upgrades in industrial facilities.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ms9th\" data-start=\"500\" data-end=\"517\"\u003eApplications:\u003c\/h3\u003e\n\u003cp data-start=\"519\" data-end=\"965\"\u003eThe Westinghouse EHD315LA02 breaker is used in commercial buildings, manufacturing facilities, utility distribution systems, HVAC equipment, motor control applications, and industrial machinery panels to provide dependable short-circuit and overload protection. It is commonly deployed in three-phase electrical systems where stable fault interruption, selective coordination, and equipment protection are critical for continuous plant operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5hg6bl\" data-start=\"967\" data-end=\"996\"\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cp data-start=\"998\" data-end=\"1662\"\u003e• Manufacturer: Westinghouse\u003cbr data-start=\"1026\" data-end=\"1029\"\u003e• Model \/ Part Number: EHD315LA02\u003cbr data-start=\"1062\" data-end=\"1065\"\u003e• Product Type: Molded Case Circuit Breaker\u003cbr data-start=\"1108\" data-end=\"1111\"\u003e• Breaker Series: EHD Frame\u003cbr data-start=\"1138\" data-end=\"1141\"\u003e• Rated Current: 15A\u003cbr data-start=\"1161\" data-end=\"1164\"\u003e• Poles: 3-Pole\u003cbr data-start=\"1179\" data-end=\"1182\"\u003e• Voltage Rating: 480 VAC \/ 250 VDC\u003cbr data-start=\"1217\" data-end=\"1220\"\u003e• Interrupting Capacity: 14 kA\u003cbr data-start=\"1250\" data-end=\"1253\" data-is-only-node=\"\"\u003e• Trip Unit Type: Thermal-Magnetic\u003cbr data-start=\"1287\" data-end=\"1290\"\u003e• Frequency: 50\/60 Hz\u003cbr data-start=\"1311\" data-end=\"1314\"\u003e• Auxiliary Contact: EHD14K Auxiliary\u003cbr data-start=\"1351\" data-end=\"1354\"\u003e• Mounting: Panelboard or switchboard mount\u003cbr data-start=\"1397\" data-end=\"1400\"\u003e• Application: Branch circuit and feeder protection\u003cbr data-start=\"1451\" data-end=\"1454\"\u003e• Protection Type: Overload and short-circuit protection\u003cbr data-start=\"1510\" data-end=\"1513\"\u003e• Connection Type: Line and load lug terminals\u003cbr data-start=\"1559\" data-end=\"1562\"\u003e• Installation Environment: Industrial and commercial electrical systems\u003cbr data-start=\"1634\" data-end=\"1637\"\u003e• Compliance: UL Listed\u003c\/p\u003e\n\u003ch3 data-section-id=\"1cz0398\" data-start=\"1664\" data-end=\"1688\"\u003eCommon Replacements:\u003c\/h3\u003e\n\u003cp data-start=\"1690\" data-end=\"1743\"\u003e• Eaton EHD3015A02\u003cbr data-start=\"1708\" data-end=\"1711\"\u003e• Eaton FD315\u003cbr data-start=\"1724\" data-end=\"1727\"\u003e• Eaton FDB315\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Westinghouse","offers":[{"title":"Used Surplus - Excellent Condition","offer_id":51732215824686,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0940\/0818\/1038\/files\/Ebay_website_image_520a36ac-95ba-4ad8-9957-a22eeaf43e89.jpg?v=1770598789","url":"https:\/\/plgautomation.com\/products\/westinghouse-ehd315la02-molded-case-circuit-breaker","provider":"PLG Automation ","version":"1.0","type":"link"}