Industrial LG5925 Emergency Stop Module 230 Volts
Industrial LG5925 Emergency Stop Module 230 Volts
Description:
Description:
The Salemaster LG5925 Emergency Stop Module is used in machine safety systems to monitor emergency stop circuits and safely remove power from hazardous equipment during fault or stop conditions. Commonly installed in manufacturing machinery, conveyor systems, packaging equipment, presses, and automated production lines requiring safety-rated emergency stop functionality. Maintenance teams, OEM machine builders, and system integrators use this module for safety system upgrades, machine retrofits, and replacement of failed safety relays.
Applications:
The Salemaster LG5925 emergency stop module is commonly used in emergency stop circuits, safety gate monitoring systems, furnace safety applications, and machine guarding systems where SIL 3 and Category 4 safety performance is required. The module supports both single-channel and dual-channel emergency stop configurations with optional cross-fault detection and manual or automatic restart functions, making it suitable for industrial automation and process safety applications.
Technical Specifications:
• Manufacturer part number (MPN): LG5925
• Manufacturer: Salemaster / Dold SAFEMASTER
• Product type: Emergency stop module
• Supply voltage: 230 VAC
• Frequency: 50/60 Hz
• Function: Emergency stop and safety gate monitoring
• Safety category: Category 4 per EN ISO 13849-1
• Performance level: PL e
• Safety integrity level: SIL 3
• Channel configuration: Single-channel or dual-channel operation
• Cross-fault detection: Selectable
• Restart modes: Manual or automatic restart
• Output contacts: Up to 4 NO safety contacts depending on variant
• Contact rating: 8 A thermal current maximum
• Mounting type: 35 mm DIN rail mount
• Housing protection rating: IP40
• Terminal protection rating: IP20
• Dimensions (W x H x D): 22.5 x 90 x 121 mm
• Weight: Approximately 275 g
• Operating temperature range: -15°C to +55°C
• Approvals: UL, TÜV, CE, CSA, RoHS compliant
Common Replacements:
• Dold LG5925.48 Emergency Stop Module
• Pilz PNOZ X3 Safety Relay
• Siemens 3TK28 Safety Relay Module
Share