Schneider Electric XCS-A701 Safety Limit Switch
Schneider Electric XCS-A701 Safety Limit Switch
Description:
Schneider Electric's Telemecanique XCS-A701 Safety Limit Switch is a rugged metal-bodied Limit Switch designed to monitor guard doors and access points in industrial automation, delivering positive-opening monitoring for machine interlocks in robotic cells, packaging lines, conveyors, CNCs, and other automated equipment. This 2 NC + 1 NO limit switch (XCS Safety Switches, XCSA series) uses a key-operated turret head and slow-break, break-before-make contact operation to ensure safe disconnection when guards are opened. It provides positive-opening NC contacts and a rated operational current of 6 A at 120 V AC and 3 A at 240 V AC (AC-15, A300), with a rated insulation voltage of 500 V. Wiring is via screw terminals, with a single Pg13.5 threaded entry, and mounting is suitable for machine or panel installations. The enclosure is metal (Zamak) and IP67-rated, built for harsh industrial environments and compliant with IEC 60947-5-1, IEC 60204-1, ISO 14119, UL 508, and CSA C22.2 No. 14. In use, it is commonly deployed on automated production lines, robotic work cells, material handling systems, and packaging machinery where durable interlocks prevent hazardous operation when protective guards are opened. Common replacements include Siemens SE5232-0HC05 Safety Position Switch.
Share