Time Mark 91016601 Current-Sensitive Relay MAuto Start-Up
Time Mark 91016601 Current-Sensitive Relay MAuto Start-Up
Description:
The Time Mark 91016601 Current Sensitive Relay monitors single-phase AC motor current and provides adjustable start-up delay, current trip, and trip delay to protect motors from sustained overcurrent while ignoring normal inrush at startup. It uses SPDT contacts rated 10 A at 240 VAC resistive and operates from 120 VAC, 60 Hz with a 2.0 W power draw and a 600 VAC current transformer insulation rating, making it suitable for pumps, compressors, conveyors, fans, and HVAC equipment. Programmable settings include current trip ranges (2–20 A on 1 CT pass, 1–10 A on 2 passes, 0.5–5 A on 4 passes), start-up delay 0.5–6 s, trip delay 0.2–2.5 s, and selectable automatic or manual reset; it serves as a common replacement for Time Mark 2734 series (2734-120VAC, 2734-24VAC) and features a plug-in socket mount in an ABS enclosure for straightforward integration in industrial machinery.
Share